Product Characteristics | ||||
---|---|---|---|---|
Model No. | 20000TL+ (20KW) | 30000TL+ (30KW) | 50000TL+ (50KW) | 60000TL+ (60KW) |
Warranty | ||||
Product Warranty (Min) | 5 Years | 5 Years | 5 Years | 5 Years |
Input Data(DC) | ||||
Max. DC Power | 22 KW | 33 KW | 58 KW | 68 KW |
Max. DC Voltage | 1000 V | 1000 V | 1100 V | 1100 V |
Min. DC Voltage to Start Feed In | 250 V | 250 V | 200 V | 200 V |
Max. DC Current | 66 A | 70 A | 19/28/19/28 A | 30*4 A |
MPP(T) Voltage Range | 250~800 V | 250~800 V | 200~1000 V | 200~1000 V |
No of MPP Trackers | 2 | 2 | 4 | 4 |
DC Inputs | 6 | 10 | 10 | 12 |
Output Data (AC) | ||||
Max. AC Power | 20 kW | 30 kW | 50 KW | 60 KW |
Nominal AC Power | 20 kW | 30 kW | 50 KW | 60 KW |
Output AC Voltage Range | 360~440 V | 360~440 V | 360~440 V | 360~440 V |
Nominal AC Voltage | 400 V | 400 V | 400 V | 400 V |
Max. AC Current | 33.3 A | 48 A | 66 A | 83.2 A |
Nominal AC Current | 30.3 A | 44.5 A | 60 A | 75.7 A |
Frequency Range | 45-65 Hz | 45-65 Hz | 45-65 Hz | 45-65 Hz |
Frequency | 50, 60 Hz | 50, 60 Hz | 50, 60 Hz | 50, 60 Hz |
Power Factor (cosθ) | 0.9 | 0.9 | 0.9 | 0.9 |
Distortion (THD) | < 3 % | < 3 % | < 3 % | < 3 % |
No of feed-in phases | 3 | 3 | 3 | 3 |
Max. Efficiency | 98.2 % | 98.2 % | 98.5 % | 98.8 % |
Euro Efficiency | 97.6 % | 97.5 % | 98.3 % | 98.2 % |
General Data | ||||
Dimensions (H/W/D) | 670x470x165 mm | 800x580x235 mm | 585x470x165 mm | 585x470x165 mm |
Weight | 50 Kg | 53 Kg | 58 Kg | 60 Kg |
Power Consumption at Night | #NAME? | #NAME? | #NAME? | #NAME? |
Noise Level | < 50 dB(A) | < 60 dB(A) | < 60 dB(A) | < 60 dB(A) |
Operating Temperature | -25 ~ +60 ℃ | -25 ~ +60 ℃ | -25 ~ +60 ℃ | -25 ~ +60 ℃ |
Transformer | Transformer less | Transformer less | Transformer less | Transformer less |
Protection Class | IP65 | IP65 | IP65 | IP65 |
Cooling | Natural | Natural | Fan | Fan |
interface | RS 232, RS 485, WLAN | RS 232, RS 485, WLAN | RS 232, RS 485, WLAN | RS 232, RS 485, WLAN |
Display | LCD | LCD | LCD | LCD |
Protection Features | ||||
Protection Features | Anti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid Monitoring | Anti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid Monitoring | Anti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid Monitoring | Anti Island Protection(ENS), Short Circuit Protection, Overload Protection, Overvoltage Protection, Overcurrent Protection, Overtemperature Protection, Residual Current Device (RCD), Reverse Polarity Protection, Surge Protection, DC Load Disconnector, Isolation Monitoring, Grid Monitoring |